In the daily after-sales of Shanghai Bilang, there will be many questions about the failure of the snowflake ice machine. The following editors of Bilang will edit the problems that are often encountered as follows. The maintenance methods of common failures of ice machines
1) Failure phenomenon: the compressor works but does not cool. Cause of failure: refrigerant leakage or two-way solenoid valve damage is not tightly closed.
Maintenance method: make up the leak after leak detection, add refrigerant or replace the solenoid valve
2) Trouble phenomenon: The compressor has been working for cooling, and the water pump has been working for pumping water, and the ice cubes have become thicker, but they cannot always enter the de-icing procedure to drop ice.
Causes of failure: The water temperature measuring probe is faulty, so that the intelligent control system cannot effectively sense the water temperature and work, misjudge the program error, or the controller is faulty.
Maintenance method: use a multimeter to measure the resistance of the water temperature probe (when the water temperature in the water tank is close to 0 ° C, unplug the three-core wire in the control box and test the resistance of the two wires on both sides), for example, the resistance is at 27K Above, it is judged that the controller is bad and should be replaced. If the resistance value is lower than 27K, you must disconnect any one of the two wires and adjust the resistance value between 27K and 28K by way of series resistance.
3) The machine enters the de-icing procedure (the water pump stops working and the compressor stops cooling) but the ice cubes do not fall off. Cause: The two-way solenoid valve is damaged.
Maintenance method: replace the solenoid valve body or outer coil.
4) The water shortage light is on but the machine does not automatically fill in water. Cause of failure: The valve does not open when there is no water in the pipeline or the inlet solenoid valve is faulty.
Maintenance method: Check the water intake of the pipeline. If there is no water, open the water channel and restart the machine. Replace the water inlet solenoid valve if it is faulty.
5) The compressor is working but the water pump has not been working (no running water). The cause of the failure: the water pump is damaged or the internal scale of the water pump is clogged.
Maintenance method: clean the pump or replace it.
Shanghai Bilang Instrument Manufacturing Co., Ltd. experimental snowflake ice machine, small snowflake ice machine, using stainless steel shell, imported compressor without noise, our company's snowflake ice machine has professional technical engineers, our company's snowflake ice machine One year warranty and lifetime maintenance.