Data network comprehensive monitoring solution
1. User needs analysis
The network centralized monitoring system is an efficient system that provides users with centralized monitoring, centralized maintenance, and centralized fault analysis. The design goal of this solution is to comprehensively cover the enterprise's data communication network, and provide network management personnel with tools to quickly locate network faults and solve network problems.
The system is divided into two parts: network fault monitoring tools and business performance monitoring. Users can select all or part of the components according to their needs.
The network monitoring system is mainly for the analysis, tracking and statistics of network data packets for the engineers responsible for network maintenance. The system also provides integrated SNMP and RMON statistical functions. The monitoring system provides users with the following functions:
(1) Provide a centralized monitoring system for the network. Analyze and test each network segment of the network through the center. Thereby establishing a fast and centralized fault analysis and diagnosis system.
(2) Provide statistical analysis functions for all network segments covered. Through the company's network probes, RMON-based statistics and analysis functions can be performed on the network. Statistical items include traffic distribution, protocol distribution, user distribution, etc.
(3) Provide a fault diagnosis system for experts, evaluate the network quality, and provide suggestions and assistance for the analysis and elimination of network faults.
(4) Provide 100% data capture and storage functions, users can capture and decode data packets on the central platform.
(5) Support decoding and statistics functions of more than 400 protocols.
The service analysis system is a performance test system for IP services that needs to be developed for users' increasingly strong service guarantees. Through this system, operators can quickly and effectively test, publish and store user service quality. At the same time, overall and segmented quality tests can be performed on the network to quickly locate and isolate network faults. The test system provides users with the following functions:
(1) Comprehensive network quality testing, service quality testing, and network protocol analysis functions. Completely solved the problem of inconsistency between the service quality perceived by users in the past and the network quality parameters tested by operators. Engineers can carry out user simulation tests on the central platform, as well as segment tests on the network.
(2) Unique Web Agent technology provides a very convenient way to test and release. Users only need to log in to the specified website, the system can automatically test the user's business quality and publish the test results on the Web Server.
(3) Provide integrated functions for long-term business quality data, including quality change trends, quality alarms, and SLA functions.
This recommendation is based on the network structure of an enterprise. The monitoring system includes an overall plan and a distributed implementation plan.
(1) This plan mainly describes the structure of the overall plan. The overall plan includes all networks covering the enterprise, including LAN, WAN, ATM. The software and server configured in this solution include support for all the above network environments. The functions described in this solution can be applied to all Zhaoqing network tests.
(2) The mandatory configuration of this solution only includes support for the Ethernet part. As the first phase of the project, it is recommended that users implement an Ethernet monitoring system. As the second and third steps, a WAN and ATM monitoring system can be implemented.
(3) The distributed implementation of the project only needs to expand the test module, and no additional software platform and server are needed.
2 Monitoring system function configuration
2.1 Structure connection diagram of monitoring system
1) NTC is the software of the fault monitoring center. It runs in the network management center and performs comprehensive statistics on the network through the RMON information collected by each network probe. At the same time, data can be captured and decoded on the network.
2) If you need to conduct business performance analysis, you need to install Application Analyzer analysis software in the monitoring center.
![]()
The overall configuration of the system is shown in the figure. According to the needs of users, 7 distributed network probes, a set of fault detection center software and a set of business analysis center software are required. This solution can further increase the ATM and E1 test modules according to the needs of users, without adding software configuration.
2.2 Test plan design
Steps for the test system to perform network failure analysis:
(1) Users can observe NTC's automatic network performance scan (radar chart) and network snapshot to see if there is a fault on the network and the point in time when the fault occurred.
(2) Observe the RMON statistical data and baseline of the network, including protocol analysis, user analysis, packet length distribution, utilization rate change, etc.
(3) Locate the problematic address (using TOP N function) and observe the statistical information of the specific address.
(4) Start the data capture and decoding functions and analyze the seven-layer decoding of the data packet.
(5) Perform network troubleshooting according to the recommendations given by the expert system.
The business performance test is a unique function of the monitoring system. The steps of the test system to perform user test functions are as follows:
(1) The user opens the browser and accesses the URL address announced by the administrator.
(2) The user clicks the Web Agent button to load the Web Agent.
(3) Simulation Center automatically discovers users who have logged in, and tests the user's business performance such as TCP throughput, delay, jitter; FTP / HTTP throughput and other parameters.
(4) Simulation Center transmits the test results to the integrated Sybase database. The database searches the user's history and adds the latest results.
(5) Form the user's test results into the business performance baseline and publish it on the business quality announcement Web Server.
(6) The user closes the browser, the test agent disappears automatically, and the test ends.
![]()
Test center configuration
3 Monitoring system function configuration instructions
3.1 System capacity configuration instructions
1) The system includes 7 10 / 100M Ethernet test modules, including 4 fiber-optic interface Ethernet test modules.
2) Using a fault monitoring center, all test modules can be controlled and collected at the same time.
3) The system allows up to 20 administrators to access the fault monitoring center locally or remotely for network analysis and statistics.
4) The business testing center can support the business testing of 10 users at the same time.
3.2 Hardware configuration instructions
Server type
Function application
The user performance monitoring server provides users with business test functions. Control Web Agent, Cisco SAA and Permanent Agent. Provide end users with packet loss, delay, jitter, and throughput tests to determine the download rate and delay of user-specified websites. Fault points
Click to enter the booth of Beijing Tongtest Technology Co., Ltd. to see more I want to contribute


Sweep, welcome attention
Official WeChat of Educational Equipment Procurement Network
Master the latest and most authoritative information in the education equipment industry
Copyright and Disclaimer:
â‘ The copyright of all works on this website that indicate "Source: China Education Equipment Purchasing Network" belongs to China Education Equipment Purchasing Network, and may not be reproduced, edited or used in other ways without authorization from this website. Works that have been authorized by this website should be used within the scope of authorization, and indicate "Source: China Education Equipment Purchase Network". Violators of this website will be held accountable for legal liabilities.
â‘¡ All works on this website that indicate "Source: XXX (non-this website)" are reproduced from other media. The purpose of this reprint is to transmit more information. This does not mean that this website agrees with its views and is responsible for its authenticity. Take direct responsibility and joint liability for infringement of such works. If other media, websites or individuals download and use it from this website, they must keep the "source of the manuscript" indicated on this website, and bear the legal responsibility of copyright and other.
â‘¢ If the content of the work, copyright and other issues are involved, please contact this website within two weeks from the date of publication of the work, otherwise it is deemed to waive the relevant rights.
About Website Contact Us Online Advertising Publication Member Service Beginner Member Agreement Site Map I want to contribute Site Recruitment
Customer Telephone E-mail: Address: Capital Institute of Physical Education, No. 11, North Third Ring West Road, Haidian District, Beijing


Beijing Public Security Bureau Haidian Branch Record No. 1101083696 Beijing ICP Certificate No. 050368 Beijing ICP No. 05038339 Business License
Copyright? 2004-2020 Beijing Tiandi Yitong Education Technology Co., Ltd. All rights reserved
var _hmt = _hmt || []; (function () {var hm = document.createElement ("script"); hm.src = "//hm.baidu.com/hm.js?7bba69eb3c3832c2e03cd64b565141fc"; var s = document .getElementsByTagName ("script") [0]; s.parentNode.insertBefore (hm, s);}) (); (function () {var bp = document.createElement ('script'); var curProtocol = window.location .protocol.split (':') [0]; if (curProtocol === 'https') {bp.src = 'https://zz.bdstatic.com/linksubmit/push.js';} else {bp .src = 'http://push.zhanzhang.baidu.com/push.js';} var s = document.getElementsByTagName ("script") [0]; s.parentNode.insertBefore (bp, s);}) ();
Spring
Do you want to make your Garden more beautiful and attractive?
25 Inch metal outdoor flowers Garden Stakes decor made from high grade rust-proof metal and 1.8 inch glass bead (glow in dark).
Place them in your garden, yard or anywhere you want, they will bring more refreshing feel of nature.
Durable, waterproof and rust-proof, widely use at indoor and outdoor, such as living room, office, kitchen, garden, yard, patio, planter pot and so on.
Important:
The glass ball glows faintly light automatically at dark place. If they do not emit light, please left them in direct sunlight to absorb the sunshine.
Spring,Storage Box,Red Storage Bins,Extra Large Toy Box,Lego Storage Case
HISMOK(SHENZHEN)TECHNOLOGY CO.,LTD , https://www.fzwilltrade.com