Salt spray test chamber: inspection procedure and calculation method of salt spray settlement

Inspection steps for the amount of salt spray in the salt spray test chamber:

1. Fix the glass funnel on the measuring cylinder and place it on the position of the specified measuring point;

2. Raise the temperature of the test equipment to the required temperature and spray continuously for 16h;

3. Take out the measuring cylinder immediately after the spraying is stopped and record the amount of solution collected.

Method for calculating salt fog settlement in salt spray test chamber:

According to the recorded data, the salt fog settlement at each measurement point is calculated as follows: G ﹦ V / t

In the formula:

G ------- The amount of salt fog settling, in units of milliliters per 80 square centimeters per hour [ml / (h • 80cm2)]

V ------- The amount of salt fog settling, in units of milliliters per 80 square centimeters [ml / 80cm2]

t -------- Continuous spray time, unit is hour (h)

For more details, please visit the official website of Beijing Yashilin: http: // or call the sales department of Beijing Yashilin.